バナー
ホーム

急速温度変化試験室

急速温度変化試験室

  • Operation Notes for Rapid Temperature Change Test Chambers: Don't Overlook These Key Points
    Dec 02, 2025
        As a core device for environmental reliability testing, the rapid temperature change test chamber is widely used in electronics, automotive, and other industries due to its ability to achieve drastic temperature variations. Its high/low temperature performance and rapid temperature change capability directly affect test data accuracy, operational safety, and equipment service life. Below are the core operational precautions: I. Pre-Startup: Conduct Basic Inspections Comprehensive pre-startup checks are critical for preventing malfunctions, focusing on "medium, status, and connections": Medium & Pipeline Inspection: Verify that the cooling system's liquid level and pressure meet standards, with no pipeline leakage or blockage. Check the refrigerant system pressure to avoid cooling failure or compressor damage due to insufficient medium. Equipment Status Confirmation: Ensure the chamber door seal is intact (poor sealing reduces temperature change rate and increases energy consumption). Keep the chamber interior clean and free of debris, and ensure sensor surfaces are free of oil and dust to avoid temperature measurement interference. Electrical Connection Check: Confirm power and control cables are securely connected, and the grounding resistance complies with specifications (≤4Ω) to prevent electric leakage or electromagnetic interference. II. Sample Placement: Prioritize Scientific Standards Proper sample placement ensures test authenticity, adhering to the principles of "no interference, no overrun, easy monitoring": Weight & Volume Control: Total sample weight must not exceed the rated load. Single sample volume ≤ 1/3 of the working chamber. Maintain a distance of ≥5cm from the chamber walls and sensors to avoid uneven local temperature caused by airflow blockage. Sample Compatibility: Never place flammable, explosive, corrosive, or toxic samples. For heat-generating samples, specify power in advance to ensure compatibility with the equipment's heat dissipation capacity and prevent overload. Fixing & Wiring Specifications: Secure samples with dedicated brackets to prevent displacement during temperature changes. Use high-temperature resistant insulated wires for energized tests to avoid short circuits and aging. III. Operation Process: Precise Monitoring & Adjustment Dynamic monitoring during operation guarantees test reliability, focusing on "parameters, status, and abnormalities": Parameter Setting & Verification: Set temperature range, change rate, and other parameters per standards and re-verify. Adjust only after the equipment stabilizes to avoid system fluctuations. Operation Status Monitoring: Real-time monitor temperature curves and indicator lights to ensure the deviation between actual and set temperatures ≤ ±1℃. Listen for abnormal noises from components like the compressor and shut down immediately if detected. Abnormal Handling: If the equipment triggers over-temperature, overload, or other protections, do not force reset. First troubleshoot the cause (e.g., abnormal sample heating, unstable voltage) before restarting. IV. Post-Test: Standardized Shutdown & Maintenance Proper post-test procedures extend equipment life, following three steps: "cooling, cleaning, and recording": Gradual Cooling to Prevent Damage: After testing, open the door only when the chamber temperature drops to room temperature (20-25℃) and the temperature difference with the outside ≤10℃, avoiding sample condensation or chamber wall damage. Cleaning & Maintenance: Wipe the chamber interior and door seal with a dry cloth. Use dedicated cleaners for leaked substances. Remove dust from the equipment exterior to ensure unobstructed heat dissipation. Data & Status Recording: Document test parameters, curves, and abnormalities. After turning off the power, cut off the cooling medium supply and organize wires and brackets. V. Long-Term Maintenance: Extend Equipment Lifespan Regular maintenance prolongs service life: Monthly: Check the door seal elasticity and replace if aged. Quarterly: Clean the condenser and evaporator. Annually: Arrange professional inspection and maintenance of the compressor and refrigeration system. The core of test chamber operation is "safety first, standardized operation, and precise monitoring." Strict adherence to the above precautions ensures safety, reliable test data, and extended equipment life, providing strong support for product reliability verification.
    続きを読む
  • 急速温度変化試験装置の特徴の紹介 急速温度変化試験装置の特徴の紹介
    Jun 04, 2025
    急速温度変化試験室は、航空宇宙製品、情報電子機器、材料、電気電子製品、各種電子部品などにおいて、急速な温度変化の条件下での製品の性能指標を試験するのに適しています。急速温度変化試験装置の特徴:1. 先進的かつ合理的な構造設計を採用し、国際的に先進的な製品と機能部品を搭載することで、長期にわたる安定性、安全性、信頼性の高い生産ニーズを満たします。これらの用途における加工・生産要件を満たし、操作、保守、使用においてユーザーフレンドリーで、長寿命、魅力的なデザイン、そしてユーザーフレンドリーなインターフェースにより、ユーザーの操作と監視体験を簡素化・向上させます。2. 機器の主要コンポーネントは、機械全体の品質と性能を確保するために、国際的に有名なブランドの高品質な製品から選択されています。3. 完璧な設備性能と操作しやすいマンマシン対話機能。4. 独立した知的財産権と意匠特許を持ち、環境試験室のコア技術を習得する。5. 制御装置は日本から輸入したオリジナル「Youyikong」UMC1200を採用しており、遠隔監視が可能です。6. 冷凍システムはフランスのTaikang社製のオリジナルコンプレッサーユニットを採用し、凝縮水トレイを備えています。7. コアとなる電気部品はすべてシュナイダーなどの有名ブランドの輸入品です。8.海外の環境試験装置の先進的な設計理念に従い、水と電気を分離します。9.浅いタンク加湿、斬新でユニークな引き出し式給水方式、超大型タンク設計。10. スタジオの底部には排水溝の設計が採用されており、蒸気の凝縮を防ぎ、テストワークピースの保護を最大限に高めます。11. 照明システムにはフィリップスキットを採用し、観察窓には漏斗型のデザインを採用してより広い視野を提供します。12. より安全な操作を実現する独自の漏れ防止設計。
    続きを読む
  • 高温および低温試験室の基本的なトラブルシューティング方法 高温および低温試験室の基本的なトラブルシューティング方法
    Oct 16, 2024
    高温および低温試験室の基本的なトラブルシューティング方法:1、高温および低温試験装置。高温試験では、温度変化が試験温度値に達しない場合は、電気システムを検査し、障害を1つずつ排除することができます。温度がゆっくりと上昇する場合は、空気循環システムをチェックして、空気循環の調整バッフルが正常に開いているかどうかを確認する必要があります。そうでない場合は、空気循環のモーターをチェックしてください。動作は正常ですか。温度オーバーシュートがひどい場合は、PID設定パラメータを調整する必要があります。温度が直接上昇し、過熱保護されている場合は、コントローラが故障し、制御機器を交換する必要があります。2、高温および低温試験装置が試験操作中に突然故障した場合、対応する故障表示プロンプトと可聴警報プロンプトが制御装置に表示されます。操作者は、装置の操作と使用におけるトラブルシューティングの章を参照して、どのタイプの故障に属するかを迅速に識別し、専門の担当者に迅速にトラブルシューティングを依頼して、実験の正常な進行を確保できます。その他の環境試験装置では、使用中に他の現象が発生する可能性があるため、それらを具体的に分析して排除する必要があります。環境試験装置の定期的なメンテナンスと維持、冷凍システムのコンデンサーの定期的な清掃、指示に従った可動部品の潤滑、および電気制御システムの定期的なメンテナンスと検査は、重要なタスクです。3、高温および低温試験装置の低温が試験指標を満たさない場合は、温度変化を観察し、温度が非常にゆっくりと低下するか、または特定の値に達した後に温度が回復する傾向があるかどうかを確認する必要があります。前者は、低温試験を行う前に作業室が乾燥しているかどうかを確認する必要があります。これにより、作業室を乾燥した状態に保ってから、試験サンプルを作業室に入れてさらに試験することができます。作業室に配置された試験サンプルが多すぎて、作業室内の空気が完全に循環しない場合は、上記の理由を排除した後、冷凍システムの障害であるかどうかを検討する必要があります。この場合、メンテナンスのためにLab Companionメーカーの専門担当者を雇う必要があります。後者の現象は、機器の使用環境が悪いために発生します。機器の配置温度と場所(ボックスと壁の間の距離)は、要件(機器の操作手順に指定されている)を満たしている必要があります。現在、当社の主な製品には、高温・低温試験室、急速温度変化試験室、恒温恒湿試験室、高温・低温衝撃試験室などがあります。
    続きを読む

伝言を残す

伝言を残す
弊社の製品にご興味があり、詳細を知りたい場合は、こちらにメッセージを残してください。できるだけ早く返信させていただきます。
提出する

ホーム

製品

ワッツアップ

お問い合わせ